EC-3A & B FOR UN-INSULATED WOOD OR CONCRETE DECKS

The uniformity in method and design offered with RPS Expansion Curb and Wall Cant Curb provides the excellent flashing termination point and ensures a water-tight installation.

Inside and outside corners, as well as sloping end sections, are available to complement the installation.  "S" shaped connection clips and "V" shaped spreader clips are supplied for easy erection and alignment.  Fabricated of 18 gauge galvanized steel with attached wood nailer, 1-1/2" thick 3# density rigid fiberglass board insulation, and tee-bar reinforcing.

SPECIFICATION

Furnish and install RPS EXPANSION CURB and RPS WALL CANT CURB as manufactured by Roof Products & Systems Corporation, Bensenville, IL, at all locations shown on drawings. Expansion Curb and Wall Cant Curb shall include inside and outside corners and sloping end sections to maintain uniformity as shown on drawings.

Expansion Curb and Wall Cant Curb shall be fabricated of 18 gauge galvanized steel with built-in cant at the bottom, tee-bar reinforced, with factory installed wood nailer, and shall be insulated with 1-1/2" thick, 3# density rigid fiberglass board.  Standard curb height to be 8" unless otherwise shown on drawings. Each section of two sided Expansion Curb shall include two- 6" long "V" shaped spreader clips and two- "S" connector clips.  Each section of Wall Cant Curb shall include only one- "S" connector clip.  On all decks without insulation use RPS Model EC-3A with built-in cant.  Use RPS Model EC-3B if additional field installed insulation is required.

CAD Drawing

EC-2A & B STYLE     EC- 3A & B SUBMITTAL SHEET     EC-4A & B STYLE


All information is subject to change without notice. Dimensions and specifications shown are within manufacturing tolerances.
© Copyright Commercial Products Group of Hart & Cooley, Inc., November 2007. All Rights Reserved.